.\" Copyright (c) 1994, 1996, 1997 |
|
.\" The Regents of the University of California. All rights reserved. |
|
.\" |
|
.\" Redistribution and use in source and binary forms, with or without |
|
.\" modification, are permitted provided that: (1) source code distributions |
|
.\" retain the above copyright notice and this paragraph in its entirety, (2) |
|
.\" distributions including binary code include the above copyright notice and |
|
.\" this paragraph in its entirety in the documentation or other materials |
|
.\" provided with the distribution, and (3) all advertising materials mentioning |
|
.\" features or use of this software display the following acknowledgement: |
|
.\" ``This product includes software developed by the University of California, |
|
.\" Lawrence Berkeley Laboratory and its contributors.'' Neither the name of |
|
.\" the University nor the names of its contributors may be used to endorse |
|
.\" or promote products derived from this software without specific prior |
|
.\" written permission. |
|
.\" THIS SOFTWARE IS PROVIDED ``AS IS'' AND WITHOUT ANY EXPRESS OR IMPLIED |
|
.\" WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF |
|
.\" MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. |
|
.\" |
|
.TH PCAP_CAN_SET_RFMON 3PCAP "31 July 2016" |
|
.SH NAME |
|
pcap_can_set_rfmon \- check whether monitor mode can be set for a |
|
not-yet-activated capture handle |
|
.SH SYNOPSIS |
|
.nf |
|
.ft B |
|
#include <pcap/pcap.h> |
|
.LP |
|
.ft B |
|
int pcap_can_set_rfmon(pcap_t *p); |
|
.ft |
|
.fi |
|
.SH DESCRIPTION |
|
.B pcap_can_set_rfmon() |
|
checks whether monitor mode could be set on a capture handle when |
|
the handle is activated. |
|
.SH RETURN VALUE |
|
.B pcap_can_set_rfmon() |
|
returns 0 if monitor mode could not be set, |
|
1 if monitor mode could be set, and a negative value on error. |
|
A negative return value indicates what error condition occurred. |
|
The possible error values are: |
|
.TP |
|
.B PCAP_ERROR_NO_SUCH_DEVICE |
|
The capture source specified when the handle was created doesn't |
|
exist. |
|
.TP |
|
.B PCAP_ERROR_PERM_DENIED |
|
The process doesn't have permission to check whether monitor mode |
|
could be supported. |
|
.TP |
|
.B PCAP_ERROR_ACTIVATED |
|
The capture handle has already been activated. |
|
.TP |
|
.B PCAP_ERROR |
|
Another error occurred. |
|
.B pcap_geterr() |
|
or |
|
.B pcap_perror() |
|
may be called with |
|
.I p |
|
as an argument to fetch or display a message describing the error. |
|
.LP |
|
Additional error codes may be added in the future; a program should |
|
check for 0, 1, and negative, return codes, and treat all negative |
|
return codes as errors. |
|
.B pcap_statustostr() |
|
can be called, with a warning or error code as an argument, to fetch a |
|
message describing the warning or error code. |
|
.SH SEE ALSO |
|
pcap(3PCAP), pcap_create(3PCAP), pcap_activate(3PCAP), |
|
pcap_set_rfmon(3PCAP)
|
|
|